Please use this identifier to cite or link to this item: http://hdl.handle.net/10174/38821

Title: Floating photovoltaic systems: photovoltaic cable submersion testing and potential impacts
Authors: Rebelo, Ricardo
Fialho, Luis
Novais, Maria Helena
Keywords: Electrical Insulation
Floating PV
Solar Energy
Water Quality
Issue Date: 2024
Publisher: F1000 Research Ltd
Citation: Rebelo R., Fialho L. & M.H. Novais, 2024. Floating photovoltaic systems: photovoltaic cable submersion testing and potential impacts. Open Research Europe, 3, art. no. 61. https://doi.org/10.12688/openreseurope.15122.2
Abstract: Background: Floating photovoltaics (FPV) is an emerging technology that is gaining attention worldwide. However, little information is still available on its possible impacts in the aquatic ecosystems, as well as on the durability of its components. Therefore, this work intends to provide a contribution to this field, analysing possible obstacles that can compromise the performance of this technology, adding to an increase of its reliability and assessing possible impacts. The problem under study is related to the potential submersion of photovoltaic cables, that can lead to a degradation of its electrical insulation capabilities and, consequently, higher energy production losses and water contamination. Methods: In the present study, the submersion of photovoltaic cables (with two different insulation materials) in freshwater and artificial seawater was tested, in order to replicate real life conditions, when FPV systems are located in reservoirs or in the marine environment. Electrical insulation tests were carried out weekly to assess possible cable degradation, the physical-chemical characteristics of the water were also periodically monitored, complemented by analysis to detect traces of copper and microplastics in the water. Results: The results showed that the submersion of photovoltaic cables with rubber sheath in saltwater can lead to a cable accelerated degradation, with reduction of its electrical insulation and, consequently, copper release into the aquatic environment. Conclusions: The test results pointed a probable relationship between submersion of cables with rubber outer shell and water freezing temperatures and the occurrence of accelerated degradation of the cable insulation layer. Reduced insulation resistance values were measured in this cable type after the occurrence of such temperatures, both in salt and freshwater, the cable presented visible exterior degradation signs. For this case copper residues were detected in the water.
URI: http://hdl.handle.net/10174/38821
Type: article
Appears in Collections:CI-ER - Publicações - Artigos em Revistas Internacionais Com Arbitragem Científica

Files in This Item:

File Description SizeFormat
Rebelo et al 2024 Open Research Europe.pdf3.57 MBAdobe PDFView/Open
FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpaceOrkut
Formato BibTex mendeley Endnote Logotipo do DeGóis 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Dspace Dspace
DSpace Software, version 1.6.2 Copyright © 2002-2008 MIT and Hewlett-Packard - Feedback
UEvora B-On Curriculum DeGois